May 18, 2011

Process Intensification - 3, Micro Reactors

In the series, the next most interesting & commonly known equipment is the micro reactors, the buzz word of the current times in process engineering. First article on introduction of PI is Here & Second article on Static Mixers as PI equipment is Here.

As name suggests - Micro - means mini - reactor is a device in which chemical reactions take place in a confinement with typical lateral dimensions below 1 mm; the most typical form of such confinement are microchannels or capillaries. The microreactor is usually a continuous flow reactor. Microreactors offer many advantages over conventional scale reactors, including vast improvements in energy efficiency, reaction speed and yield, safety, reliability, scalability.



I am not going in to too much theory & I am directly putting up examples for quick understanding of underlying principles & benefits due to the changes.

So, Let us first see the advantages & disadvantages of Micro Reactor Technology (MRT).

Benefits
  1. Very high surface to volume ratio

  2. To see this more clearly, I am using one example from Sigmaaldrich website. Let us understand it by comparing a case of CSTR & MRT.

    Case-1 CSTR
    This is an example of CSTR of 1 KL at 500 rpm for an exothermic case with outside cooling.



    In this case you can see that temperature distribution os very uneven & hence the reaction control, quality etc are not uniform.

    Case-2 MRT

    In this case, the temperature distribution is so uniform that quality is controlled in a much better way.

    Therefore, because of very high surface area / unit volume of reaction mass, the control on heat transfer is very very good compared to CSTR. This is very important factor, if you can realize the importance of this aspect of any reactor. This factor alone can result into many significant differences e.g. very good conversion, lower level of impurities, higher yield etc.

    Just to see the impact Do you Know, what are the typical values of surface area to per unit volume - This is

    - 6 Sq Meter / cubic Meter of reactor volume for CSTR
    - 100 Sq Meter / cubic Meter of reactor volume for 100 mL glass flask
    - 20000 Sq Meter / cubic Meter of reactor volume for Micro Reactor.

    Yes, it is almost 15 times more in Laboratory & this is the main area where most of the lab scale & bigger scale differences occur. AND Oh! my GOD - 3000 times more in MRT. My suggestion - Buddy forget Micro reactors, invent something which can just give you say 1000 Sq Meter / Cubic meter of volume, It can do wonders - believe me

  3. Better mixing

  4. Since, the micro volumes are mixed in a capillary, the mixing is instant & uniform. Due to very high length of the mixing path per unit volume compared to any other reactor the design is very effective. Therefore, the unformity of mass is almost same in the entire reactor and hence more uniformity in quality can be achieved.

    This is very important aspect in some of the industries related to performance chemicals e.g. ethoxylates where more & more unformity (peak ethoxylates) is desirable.

    Ultimately this results in very good purity of product by suppressing the impurities formation and very high yields due to the same factor.

  5. Instant removal of the material out of the reaction zone

  6. The holding volumes or system volumes are so low that they do not affect the reactions & therefore even equilibrium reactions can achieve higher per pass conversions due to very quick removal of products as soon as they are formed.

    Therefore, this is very important in case of equilibrium driven reactions or where yield are impacted significantly due to side reactions and where the product is sequentially converted to other byproducts

    Suppose you are conducting one reaction A -> B -> C & your final product is B. Also consider the case where A ->B & A -> C reactions are happening. Then in a CSTR you will either reduce the conversion of A to limit concentration of C or you will optimize parameters to suppress C in second case. But in MRT, there is very little formation of C in either case due to very low volumes especially in first reaction.

    Hence, you can have very high conversion saving recycles of A and higher yield due to lesser formation of C.

  7. Improved Safety

  8. Since the volumes handled are very less - micro litres - the hazardous reactions can safely be carried out in MRT and very little efforts & investment is required in case of hazardous / run away reactions e.g. polymerisation or ethoxylation or explosive materials handling.

    Therefore, investments required on safety systems, instrumentations, losses due to release of chemicals / pressures etc & hence they are environment friendly also.

  9. Very High Heat Flux

  10. Microreactors typically have heat exchange coefficients of at least 1000 kW / M3 / K to 500000 kW / M3 / K vs. a few kilowatts in conventional glassware (1 l flask ~10 kW / M3 / K). Thus, microreactors can remove heat much more efficiently than vessels and even critical reactions where exotherms are very high & instantaneous, can be performed safely at high temperatures.

    This factor is also very important for example nitration is a very quick & highly exothermic reaction in general which can be safely carried out in MRT.

  11. Continuous Processes

  12. Microreactors are normally operated continuously. This allows no batch hold ups & higher time cycle before workup. Important aspect in case of unstable compunds where holding time results in more byproducts or side products formation & hence higher selectivity.

    Mixing in a batch process causes a very different concentration profile compared to Continuous process. In a batch, reagent A is filled in and reagent B is slowly added. Thus, B encounters initially a high excess of A. In a microreactor, A and B are mixed nearly instantly and B won't be exposed to a large excess of A. This may be an advantage or disadvantage depending on the reaction mechanism.

    So many reactions where batch is a forced neccesity due to full conversion desired, the MRT can be used as continuous option. In such cases there is no other technology available till date other than PI which can help in converting batch to continuous with 100% conversion.

  13. No Scale Up Required

  14. Since the MRT is just a module technology no further scale up is required form lab to commercial scale. Only addition of similar micro reactors will add up the capacity. This reduces product development cycle time & also losses in scale up during piloting, manpower, efforts & Energy is also saved.

Now let us understand disadvantages or rather problems in using MRT.
Concerns
  1. Only Liquid Systems

  2. MRT is still struggling in terms of handling gases & solids and only liquid liquid reactions are well performed. I see this as a area for improvement required in MRT rather than a problem. May be why solids in MRT is my first question OR when we are talking about Micro why not nano particles if any solid catalyst is required.

    Yes, reactions with solids as reactants will still be a problem.

    Regarding gases handling, the problem is not so critical its a matter of pressure handling but yes it is a concern as of now.


Hope it is useful for all of you & now you will start thinking on using them.

Get Free Updates:
*Please click on the confirmation link sent in your Spam folder of Email*

Continue to read this post...

May 03, 2011

ISO - Standard or Business - 5

Further, is it true that ISO is for people, their safety, their interest as consumer etc...etc.???

ISO Claims - "They are useful to ...........and, ultimately, to people in general in their roles as consumers and end users"

Ha...Ha...Ha....Consumers, who do not even know what for this company is having ISO. is it for product or for finance or for purchase or ......?????

HAVE YOU EVER FELT ANY PROTECTION DUE TO ISO.........

See my previous articles on ISO - Part-1, Part-2, Part-3 & Part-4.

Consumers do not know anything about ISO coverage & even for a multi product company it is not clear If all the products of this company are covered under ISO or not. ISO is safeguarding them against harmful content in the product or not. The raw material which is used in this product is having or not having any quality issue which ISO can not guarantee as purchase process is not covered under ISO. All these facts are not known to any consumer in general & still ISO claim to safeguard & to be beneficial to the consumer & end user.

Company can enjoy good image in the market becasue they only publish "ISO:9000 Certified"........other info is missing. Why???? Because blindly every one is asking for only ISO certificate.........it doesn't matter if it is only for your HR (There is no link to product in this case but this is also sufficient).

I also know multi product / multi location companies where only one certificate is used for the entire company and therefore question comes - is everything covered?

The biggest flaw, still ISO claims for safeguard of consumers...HOW???? can anyone justify this?

Fed up man...Im impatient to write more on this topic. So will stop here & may come back later if I go through this subject in future.

Learning -4 It cannot be beneficial to consumers unless it is product & value chain focused. Currently it is process focused only that too with many exclusions permitted.


Disclaimer - This is a series of my personal views on ISO systems, its implementation, Effectiveness etc. They do not carry any legal issue related to my personal views under the human right of "Freedom of Speech".

Get Free Updates:
*Please click on the confirmation link sent in your Spam folder of Email*

Continue to read this post...

April 20, 2011

Process Intensification - 2, Static Mixers

My last post was focussed on general & brief overview of process intensification abbreviated PI. The term may be new to almost half of the population but we use it somewhere or somehow knowingly or unknowingly in our current life also.

As explained earlier, the miniaturisation is the key word for PI as best & smallest explanation. However, it can be simple on one side like static mixers and very complicated like immobilized solvents for absorption & desorption OR SDR (spinning disc reactor) etc. on the other side.

So instead of discussing it in general, let us go through these specific examples of PI equipments & how can we utilize them in our life...CHEMICAL life...; our first item is - Static Mixers.



According to wikipedia, the static mixers were invented by the Arthur D. Little Company in 1965. This device was licensed to the Kenics Corporation and marketed as the Kenics Motionless Mixer.

Static Mixers
A very simple piece of equipment & very easy to understand yet fully misunderstood by many of us. The basic image of an static mixer is the take a piece of pipe & fill it with any packing and your static mixer is ready. YES.....& ......NO.

YES.....because of its general construction......NO because improper design can lead to many failures and because of that you are not using it for real applications where it is more beneficial.





These mixers can be utilized for various purposes e.g. For slow Gas & Liquid Reactions where the BCT is very high & therefore, many benefits can be achieved by using SM for this type of slow reactions. Another example where we can use them effectively are homogeneous & quick mixing of liquid liquid systems.

In such cases, the benefits are many like BCT is reduced so the capacity can be enhanced from the same size of system OR the system volume can be reduced and hence the inherent safety is increased. The yields will be better due to complete or higher utilization of GAS, more uniform product due to lesser side product formation etc.

Can you think of any other good use of static mixers???

Now Let us classify SM in broad categories & how to estimate pressure drop.

1. LPD - Low pressure drop mixers for low viscosity applications.
2. ISG - Interfacial Surface Generator for high viscosity applications.

Now to estimate the pressure drop in a SM, following is the process.
First Assume the Mixer Diameter.

  1. First Calculate the Reynold No as Nre = 6.31 w / mu D = 3161 Q sg / mu D

  2. If Nre is < 500 the flow is laminar. Use either Fig.1 for LPD or Fig.3 for LLPD or Fig.5 for ISG mixers to estimate the pressure drop per element.








  3. If Nre > 500 the flow is turbulent. The pressure drop per element is estimated from Fig.2 for LPD or Fig.4 for LLPD & Fig.6 for ISG mixers.








  4. Multipy the pressure drop per element by the number of elements to obtain the estimated pressure drop through the mixer.

  5. For turbulent flow, multiply the estimated pressure drop by the specific gravity and the correction factor K to obtain the actual pressure drop as below -

    K = 1.1 for mu upto 10 cp.
    K = 1.3 for mu from 10 to 100 cp.
    K = 1.5 for mu from 100 to 1000 cp.
    K = 1.6 for mu from 1000 to 5000 cp.


  6. For laminar flow, the pressure drop is proportional to the viscosity. So for Figures 1, 3, & 5 which are based on a fluid having a viscosity of 10,000 cps, the actual pressure drop is calculated as follows

    Actual DP = Cal DP x Actual Viscosity / 10000

  7. Now if calculated total pressure drop is more than allowable pressure drop use next higher diameter.

Some of the information & Graphs are from Staticmixers.com website.

Get Free Updates:
*Please click on the confirmation link sent in your Spam folder of Email*

Continue to read this post...

April 06, 2011

ISO - Standard or Business - 4

Continuing discussion on useless nature of ISO from previous post, the next one is on the actual spread of ISO business. This reflects how it can be utilized to earn quick money by many incompetent professionals just by using some jargons & those who are more vocal than others.
See my First Three Posts on ISO-1, ISO-2 & ISO-3

In fact, this is the best 'QUICK MONEY SCHEME' for everyone who are looking for some easy job, no actual output, only vocal & very good money for all collectively where the payee is also happy & reviever will always be happy in any case.

DO YOU AGREE.........

It is useful to suppliers to sell easily in the name of ISO systems. It is useful to so called (conformity assessment) professionals as they are very much essential in order to understand the code & implement it in the RIGHT way - hence so much employment is generated by ISO for those who can Interpret the code, it doesn't matter if they understand the technical process or value chain or not.

So purposefully the ISO code is written in such a manner that you can use the language as per your own interpretation and if you are more professional you hire some specialist & he will explain you the simple english in a complicated manner. (Without understanding your prcoesses, this is the beauty of the system that they don't need to understand your process).

And the purpose is to develop a community which can earn quickly & easily and in my personal opinion & view, this is the biggest & successful MLM system in the world. you earn & promote others to join as a consultant. Some may argue that they have a very good system of certification of consultants / experts & they are again regularly reviewed........So what......After all it is beneficial for them so they have to have some system in the eyes of customers, but no one failed.

So we can have any one as an ISO assessment specialist. The level of these specialist is such that they even do not know benchmarking - and anything told by operating person is accepted by them as a benchmark (Generally people start from worst achieved figures for continual improvement targets). Pitty???????? How can you be efficient & that's why I said this is not the fault of the system, it is implementation which is faulty. Error in the system is that it allows to take these side routes becasue of many reasons as listed one by one here and I will compile all of them at the end of this series, if possible for me because of time constraints.

These are only one or two points which I am raising through this Blog as & when they come to my mind. If I go in detail or anyone else (I would love to invite you to write your frank opinion on this issue as a guest writer) each point can become a single chapter covering its impact on entire value chain - May be in future I'll do that if time permits.

Learning -3 It is beneficial to many becasue it is made so. It should be taken as a system not as a saleable product & if MLM is stopped, it may be more useful.


Disclaimer - This is a series of my personal views on ISO systems, its implementation, Effectiveness etc. They do not carry any legal issue related to my personal views under the human right of "Freedom of Speech".